🚀 New launch promo — 10% off orders over $300. Use code LAUNCH10
Not sure which part you need? Upload a photo and we'll find it. →

Heaters Replacement Parts

152 parts in stock

Find my heater

152 products

Doulbe Barrel 6.0KW Heater 26-C3072-1 240V - Bubbles Supply
HydroQuipDoulbe Barrel 6.0KW Heater 26-C3072-1

26-C3072-1

$1010.06
5.5KW 230V Flow Thru Heater 26-0071 230V - Bubbles Supply
HydroQuip5.5KW 230V Flow Thru Heater 26-0071

26-0071

$456.76
4.0KW 230V Flow Thru Heater 73994 240V - Bubbles Supply
Caldera Spas4.0KW 230V Flow Thru Heater 73994

73994

$699.07
VS/EL/SUV 8" Heater Cable 48-0023A - Bubbles Supply
HydroQuipVS/EL/SUV 8" Heater Cable 48-0023A

48-0023A

$18.43
6.0kW 230V Triple Bend Replacement Heater C2550-3661-TI2 230V - Bubbles Supply
Therm Products6.0kW 230V Triple Bend Replacement Heater C2550-3661-TI2

C2550-3661-TI2

$532.05
5.5KW 230V Flow Thru Heater C2550-0103TT 230V - Bubbles Supply
HydroQuip5.5KW 230V Flow Thru Heater C2550-0103TT

C2550-0103TT

$411.06
5.5KW 230V Low Flow Heater E2550-0300ET-G 230V - Bubbles Supply
HydroQuip5.5KW 230V Low Flow Heater E2550-0300ET-G

E2550-0300ET-G

$1162.63
5.5KW 230V Flow-Thru Heater C2550-0800ET-G 230V - Bubbles Supply
HydroQuip5.5KW 230V Flow-Thru Heater C2550-0800ET-G

C2550-0800ET-G

$306.52
IQ2020 Heater Relay Board 77118 - Bubbles Supply
Hot Spring SpasIQ2020 Heater Relay Board 77118

77118

$695.06
5.5KW 230V 90-degree Flow Thru Heater A2550-5350ET 230V - Bubbles Supply
HydroQuip5.5KW 230V 90-degree Flow Thru Heater A2550-5350ET

A2550-5350ET

$447.58
11kW 230V Outdoor Series Heater Assembly 26-0054AF-M7-KS 230V - Bubbles Supply
HydroQuip11kW 230V Outdoor Series Heater Assembly 26-0054AF-M7-KS

26-0054AF-M7-KS

$553.88
1.0/4.0KW 120/240V Heater Assembly 6500-085 120/240V - Bubbles Supply
Sundance Spas1.0/4.0KW 120/240V Heater Assembly 6500-085

6500-085

$356.81
BP7 Spa Control 4.0KW Flow Thru Heater G6405 - Bubbles Supply
BalboaBP7 Spa Control 4.0KW Flow Thru Heater G6405

G6405

$1034.87
5.5KW 230V Flow-Thru Heater C2550-0535-TPS 230V - Bubbles Supply
Balboa5.5KW 230V Flow-Thru Heater C2550-0535-TPS

C2550-0535-TPS

$405.86
In.Xe Spa Control 4.0KW Flow Thru Heater 0602-221065-293 - Bubbles Supply
Gecko AllianceIn.Xe Spa Control 4.0KW Flow Thru Heater 0602-221065-293

0602-221065-293

$1245.06
In.Xe Spa Control 1.0/4.0KW Flow Thru Heater 0602-221066-300 - Bubbles Supply
Gecko AllianceIn.Xe Spa Control 1.0/4.0KW Flow Thru Heater 0602-221066-300

0602-221066-300

$1235.91
KP-2020 Spa Control & Spa Heater SMTD-2000-PL - Bubbles Supply
ACCKP-2020 Spa Control & Spa Heater SMTD-2000-PL

SMTD-2000-PL

$1700.00
5.5KW 230V Baptismal Heater Assembly BCS-55-3W 230V - Bubbles Supply
HydroQuip5.5KW 230V Baptismal Heater Assembly BCS-55-3W

BCS-55-3W

$842.67
5.5KW 230V Flow-Thru Heater C2550-0011 230V - Bubbles Supply
Cal Spas5.5KW 230V Flow-Thru Heater C2550-0011

C2550-0011

$415.38
4.0KW 230V Flow Thru Heater C2400-0802 230V - Bubbles Supply
Gecko Alliance4.0KW 230V Flow Thru Heater C2400-0802

C2400-0802

$456.77
BP2000 Gas Heater w/ TP700 Spaside CS800-C-7 - Bubbles Supply
HydroQuipBP2000 Gas Heater w/ TP700 Spaside CS800-C-7

CS8800-C-7

$3530.44
In.Grid External Heater Controller ACM0881 - Bubbles Supply
WellisIn.Grid External Heater Controller ACM0881

ACM0881

$354.21
Value LE 5.5KW 230V Flow Thru Heater C2550-0809-TPS 230V - Bubbles Supply
HydroQuipValue LE 5.5KW 230V Flow Thru Heater C2550-0809-TPS

C2550-0809-TPS

$412.97

About Heaters

Hot Tub Heater & Spa Heater Replacements

A failed hot tub heater or spa heater is the most common reason a tub stops reaching temperature — and with 60 OEM-matched units in stock, Bubbles Supply carries the exact replacement for most residential and commercial spas on the market today. Whether you're a service technician swapping a burned-out element assembly or an owner tackling a DIY fix, this page will help you identify the right part before you order.

How to choose the right hot tub heater

Getting the fitment right means checking four things before you add to cart:

  • Wattage and voltage. Most residential spas run a 5.5 kW / 230 V heater (e.g., the 5.5KW 230V Flow Thru Heater 26-0071). Smaller 120 V plug-and-play spas typically use a 1.0–4.0 kW assembly like the 1.0/4.0KW 120/240V Heater Assembly 6500-085. Matching wattage to your control board is non-negotiable — an undersized heater trips breakers; an oversized one can damage the pack.
  • Heater style: flow-thru vs. low-flow vs. specialty. Flow-thru heaters are the industry standard and thread directly into the plumbing manifold. If your spa uses a low-circulation pump or a two-speed pump on low speed for heating, look for a low-flow rated unit such as the 5.5KW 230V Low Flow Heater E2550-0300ET-G. Specialty configurations — 90-degree elbows, triple-bend tubes, double-barrel housings — are brand-specific and must match the original footprint.
  • Tube dimensions and connection size. Common tube diameters are 2" with lengths of 15" or longer. Verify the connection size (typically 2" unions) and compare to the product spec. The 5.5KW 230V 2" x 15" Flow Thru M7 Heater G7512 is a widely applicable example.
  • Control system compatibility. Some heaters are pre-matched to a specific spa pack. If your spa runs a Balboa VS, EL, or GL series board, confirm the heater part number through the control system, not just the spa brand. Gecko In.Xe packs, for instance, use dedicated assemblies like the In.Xe Spa Control 4.0KW Flow Thru Heater 0602-221065-293.

When in doubt, pull the old heater and read the label: wattage, voltage, and tube diameter are stamped directly on the housing in almost every case.

Brands we carry

  • Balboa Water Group — the industry's most widely installed spa control and heater ecosystem; broad model coverage from VS to EL series.
  • HydroQuip — reliable OEM supplier for many mid-market spa brands; strong flow-thru lineup.
  • Gecko Alliance — powers In.Xe, In.Grid, and related control packs with matched heater assemblies.
  • Allied Innovations — aftermarket-friendly heaters built to meet or exceed OEM specs.
  • Hot Spring Spas / Watkins — proprietary heater configurations requiring brand-specific parts.
  • Sundance Spas, Caldera Spas, Master Spa, Cal Spas, Dimension One Spas, Saratoga Spa, Dreammaker Spas, Wellis — OEM-matched units available for each brand's current and legacy spa lines.
  • Waterway, Magic Plastics, Therm Products, ACC — component and assembly suppliers covering a wide range of replacement scenarios.

Common problems this part solves

Most heater-related service calls share a short list of root causes. Match your symptom below:

Frequently asked questions

How do I know if my hot tub heater element is bad versus a flow or sensor issue?

Use a multimeter set to resistance (ohms) across the heater element terminals with power off. A healthy 5.5 kW element reads roughly 9–10 ohms. A reading of zero (short) or infinite (open circuit) confirms a failed element. Normal resistance but no heat usually points to a flow switch, pressure switch, or sensor — not the heater itself.

Can I upgrade from a 4.0 kW to a 5.5 kW heater for faster heating?

Only if your control board and breaker are rated for the higher draw. A 5.5 kW element at 240 V pulls about 23 amps; your circuit must support it. Check your spa pack's documentation — many Balboa and Gecko boards are rated for 5.5 kW, but some lower-cost packs are limited to 4.0 kW. Installing an oversized heater on an undersized board will trip breakers and can damage the pack.

Are spa heater elements universal, or do I need an exact brand match?

Not universal. While many flow-thru heaters share the same 2" tube diameter and union connections, the tube length, bend configuration, watt density, and bracket position vary by brand and model. Always cross-reference the OEM part number printed on the heater label, not just the spa brand name.

What causes a hot tub heater to fail repeatedly?

Chronic heater failures almost always trace back to one of three root causes: low water flow (dirty filter, closed valve, weak pump), high calcium hardness causing scale buildup on the element, or incorrect water chemistry corroding the element sheath. Fix the underlying cause or you'll be replacing heaters every season.

How long does a spa heater replacement typically take?

For a standard flow-thru unit with union connections, most technicians complete the swap in 30–60 minutes. Proprietary double-barrel or triple-bend configurations may require draining a section of plumbing and take longer. Have thread sealant and fresh O-rings on hand before you start.

Do I need to replace the entire heater assembly or just the element?

If the housing (manifold) is intact and not cracked, replacing only the element can save money. If the housing shows cracks, pitting, or corrosion, replace the full assembly — a leaking manifold will cause the new element to fail prematurely. Check our Heater Elements collection if you only need the element tube itself.

Related categories

If you're replacing the heater element tube only rather than the full assembly, browse our Heater Elements collection for individual replacement tubes sized to fit most spa housings.

Need help choosing?

Use our fitment selector to match the exact part for your spa.

Find my part →
🔒 Secure checkout · SSL encrypted·🇺🇸🇨🇦 Serving the US and Canada·↩️ 30-day hassle-free returns·📦 Same-day fulfillment