🚀 New launch promo — 10% off orders over $300. Use code LAUNCH10
Not sure which part you need? Upload a photo and we'll find it. →

Pressure Switches Replacement Parts

30 parts in stock

Find my pressure switche

30 products

PresAir Pressure Switch PM11120E - Bubbles Supply
PresAirPresAir Pressure Switch PM11120E

PM11120E

$72.41
Pressure Switch 73995 - Bubbles Supply
Hot Spring SpasPressure Switch 73995

73995

$169.18
Tecmark Pressure Switch 4037P - Bubbles Supply
TecmarkTecmark Pressure Switch 4037P

4037P

$39.23
Tecmark Pressure Switch 3010 - Bubbles Supply
TecmarkTecmark Pressure Switch 3010

3010

$70.77
Tecmark Pressure Switch 3903 - Bubbles Supply
TecmarkTecmark Pressure Switch 3903

3903

$50.19
SPST Pressure Switch 30408 - Bubbles Supply
BalboaSPST Pressure Switch 30408

30408

$107.16
Tecmark Pressure Switch 3029 - Bubbles Supply
TecmarkTecmark Pressure Switch 3029

3029

$69.88
1 Amp 2.0 psi Pressure Switch 34-0178 - Bubbles Supply
HydroQuip1 Amp 2.0 psi Pressure Switch 34-0178

34-0178

$58.41
Tecmark Pressure Switch 3029P - Bubbles Supply
TecmarkTecmark Pressure Switch 3029P

3029P

$51.19
Tecmark Pressure Switch 3505 - Bubbles Supply
TecmarkTecmark Pressure Switch 3505

3505

$74.39
Tecmark Pressure Switch 3906 - Bubbles Supply
TecmarkTecmark Pressure Switch 3906

3906

$44.93
Pressure Switch Cable 6560-254 - Bubbles Supply
Dimension One SpasPressure Switch Cable 6560-254

6560-254

$26.22
Tecmark Pressure Switch 3038 - Bubbles Supply
TecmarkTecmark Pressure Switch 3038

3038

$80.97
MSPA?TSPA 14" Pressure Switch Harness 9920-400124 - Bubbles Supply
Gecko AllianceMSPA?TSPA 14" Pressure Switch Harness 9920-400124

9920-400124

$44.67
Tecmark Pressure Switch 3015 - Bubbles Supply
TecmarkTecmark Pressure Switch 3015

3015

$69.85
Tecmark Pressure Switch 4755P - Bubbles Supply
TecmarkTecmark Pressure Switch 4755P

4755P

$42.47
Tecmark Pressure Switch 3902 - Bubbles Supply
TecmarkTecmark Pressure Switch 3902

3902

$46.14
Tecmark Pressure Switch 3158-EH - Bubbles Supply
TecmarkTecmark Pressure Switch 3158-EH

3158-EH

$69.69
PresAir Pressure Switch TNP411R-1.8PR - Bubbles Supply
PresAirPresAir Pressure Switch TNP411R-1.8PR

TNP411R-1.8PR

$56.84
Tecmark Pressure Switch 3037P - Bubbles Supply
TecmarkTecmark Pressure Switch 3037P

3037P

$46.85
DETC-2 Pressure Switch 510AD0249 - Bubbles Supply
Gecko AllianceDETC-2 Pressure Switch 510AD0249

510AD0249

$87.21
56" Pressure Switch Cable 21223 - Bubbles Supply
Balboa56" Pressure Switch Cable 21223

21223

$30.00
Tecmark Pressure Switch TBS-3000 - Bubbles Supply
TecmarkTecmark Pressure Switch TBS-3000

TBS-3000

$23.71

About Pressure Switches

Spa Pressure Switch Replacement Parts

A spa pressure switch is a small but critical safety device that detects water flow through your circulation or jet pump and signals the control board to energize the heater. Without a functioning pressure switch, most spa controllers will lock out the heater entirely — protecting the element from running dry. Owners and technicians replacing a failed or sticky switch will find 31 options here spanning every major control system in the market.

How to choose the right spa pressure switch

Matching a pressure switch comes down to four factors. Get all four right and the switch will drop in without calibration issues.

  • Trip pressure (psi): Most residential spas use a switch set between 1.0 and 2.5 psi. A switch set too high won't trip on low-flow systems; one set too low can false-trigger. Check your existing switch or service manual for the rated trip point — for example, the 1 Amp 2.0 psi Pressure Switch 34-0178 is a common mid-range spec.
  • Amperage rating: Low-current switches (1 A) work as signal-only devices sending a logic signal to the board. Higher-rated switches (up to 25 A) directly interrupt the heater circuit. Mixing these up can burn contacts or leave the heater unprotected. The Tecmark 25A 4000 Series Pressure Switch 4036P is a direct-switching type; confirm your wiring diagram before substituting a 1 A signal switch in its place.
  • Switch configuration (SPST vs. SPDT): Most spa applications use SPST (single-pole, single-throw) normally-open switches. The SPST Pressure Switch 30408 is a representative example. Some systems use SPDT for dual-signal feedback — verify your board's terminal labeling.
  • Port size and fitting thread: The majority of these switches use a 1/8" NPT barb or compression fitting that connects to a small nylon tube tapped off the plumbing. Confirm the port size matches your existing manifold before ordering.
  • OEM part number or brand match: If your spa is a Dimension One, Hot Spring, or Gecko-controlled system, cross-reference the OEM number printed on the switch body. Several switches in this collection — including the DETC-2 Pressure Switch 510AD0249 and Pressure Switch 73995 — are sourced directly from or engineered for specific OEM systems.

Also check cable length if your replacement needs to reach a remote junction. The Pressure Switch Cable 6560-254 and the 56" Pressure Switch Cable 21223 are available separately for systems where the harness, not the switch itself, has failed.

Brands we carry

  • Tecmark — The dominant OEM supplier for North American spa controls; their 3000 and 4000 series switches are found in more spa brands than any other single manufacturer.
  • PresAir — Precision-calibrated switches used in demanding commercial and residential applications; known for consistent trip-point accuracy across temperature ranges.
  • Balboa — Integrated control system manufacturer that specs switches to their own BP, VS, and ML series boards.
  • Gecko Alliance — Canadian controls brand; their switches are engineered for MSPA and in.touch system compatibility.
  • HydroQuip — Budget-friendly and portable-spa-focused controls; pressure switch specs tend toward lower current signal types.
  • Dimension One Spas — OEM switches designed for D1's proprietary plumbing and control architecture.
  • Hot Spring Spas — Factory-spec switches for Watkins-manufactured Hot Spring and Caldera models.

Common problems this part solves

A failed spa pressure switch is one of the most common reasons a spa heats erratically or refuses to heat at all. Typical symptoms include a heater that won't activate despite normal water flow, a control panel that displays a flow or pressure fault immediately after startup, or a spa that heats for a few minutes and then faults out when the jets cycle down to low speed. In some systems a failed switch causes the heater to run continuously without shutting off — a safety concern that warrants immediate diagnosis. For a step-by-step walkthrough of these symptoms and how to test a switch with a multimeter, see our knowledge-base guide: Troubleshooting your spa pressure switch.

Frequently asked questions

How do I know if my spa pressure switch is bad?

The fastest field test is to bypass the switch temporarily with a jumper wire (with the spa powered off first) and then restore power. If the heater now fires, the switch is the problem. You can also test continuity across the switch terminals with a multimeter while manually pressing the diaphragm — a healthy normally-open switch should show continuity when pressed and open when released. See our pressure switch troubleshooting guide for the full procedure.

Can I adjust the trip pressure on my existing switch?

Some switches have an adjustment screw on the body that shifts the trip point a fraction of a psi. However, if the switch diaphragm is cracked, the contacts are pitted, or the spring is fatigued, adjustment won't restore reliable operation. Replacement is almost always the correct fix at the cost of a typical pressure switch.

Are Tecmark 3000-series and 4000-series switches interchangeable?

Not necessarily. The series differ in amperage rating, trip pressure, and connector type. A Tecmark 3010 (1 A signal type) is not a substitute for a Tecmark 4036P (25 A direct-switching type) even though both share the same port thread. Always match the amperage and trip pressure to your original specification.

My spa shows a "FL" or "FLO" error — is that the pressure switch?

On most Balboa and Gecko boards, FL or FLO indicates the pressure switch has not closed within a set time after the pump starts. The root cause could be a failed switch, a kinked pressure tube, low water level, a clogged filter restricting flow, or an air lock. Rule out water-flow issues first, then test the switch. Our troubleshooting guide walks through each cause in sequence.

What is the difference between a pressure switch and a flow switch?

A pressure switch detects the pressure differential created by moving water — it has no moving parts in the water path, just a diaphragm and spring. A flow switch uses a paddle or vane physically deflected by moving water. Both signal the heater to enable, but they are not interchangeable; your spa is designed for one or the other based on the plumbing and control board.

Do I need to bleed the pressure tube before installing a new switch?

Yes. Air trapped in the nylon sensing tube can prevent the switch from reading pressure accurately, causing nuisance faults. After installing the new switch, loosen the fitting slightly while the pump runs to purge air, then re-tighten and confirm the heater enables normally.

Related categories

Pressure switches work alongside other sensing and safety components. Also see our Sensors collection for thermistors, flow sensors, and hi-limit sensors that work alongside your pressure switch in the heater circuit.

Need help choosing?

Use our fitment selector to match the exact part for your spa.

Find my part →
🔒 Secure checkout · SSL encrypted·🇺🇸🇨🇦 Serving the US and Canada·↩️ 30-day hassle-free returns·📦 Same-day fulfillment